MELS for General Lighting (2019)
Source
This policy defines minimum energy labeling scheme requirements for incandescent lamps, CFLi lamps, and LEDs with an Edison screw or a bayonet lamp cap.

 Lamp Power Consumption (Plamp) in Watts

  • Incandescent, CFLi, and LED with an Edison screw or a bayonet lamp cap
    • 2 tick: 0.24 √ɸΔ +0.0103ɸ ≥ Plamp > 0.17 (0.88 √ɸ + 0.049ɸ)
    • 3 tick: Plamp ≤ 0.17 x (0.88 √ɸ + 0.049ɸ)

Δɸ is the rated luminous flux in lumen.

For covered CFLi, Plamp = Pcovered CFLi x 0.95

 