MEPS for Split Type Air-Conditioners
Policy Details
MEPS for Split Type Air-Conditioners
Source
The established MEPS are:
Single/Multi Split (inverter) up to 17.6kW: COP100% ≥ 3.34
Single/Multi Split (inverter) up to 17.6kW: COPweighted ≥ 4.04
Single/Multi Split (non-inverter) up to 17.6kW: COP100% ≥ 4.04
COPweighted = 0.4 x COP100% + 0.6 x COP50%
The applicable test methods are:
- Single-split: ISO 5151:2017, Section 5.1: Cooling capacity test, climate class T1
- multi-split: ISO 15042:2017, Section 6.1: Cooling capacity test, climate class T1
- All (for standby power): IEC 62301:2005 or IEC 62301:2011, Section 5.3.1 or 5.3.2 of IEC 62301:2005 or Section 5.3.2, 5.3.3 or 5.3.4 of IEC 62301:2011, climate class Nil
Asia and Pacific
Singapore*
Mandatory
Minimum Performance Standard
Adopted
&
Revised
Adopted
Revised
Updated by CLASP
ISO 15042:2017, Section 6.1: Cooling capacity test, climate class T1
ISO 5151:2017, Section 5.1: Cooling capacity test, Climate class T1
IEC 62301:2005 or IEC 62301:2011, Section 5.3.1 or 5.3.2 of IEC 62301:2005 or Section 5.3.2, 5.3.3 or 5.3.4 of IEC 62301:2011, Climate class Nil
Fuel Types
Electricity
Related Topics
Products Covered
Room ACs - Stationary ACs