INTE E14-2 2015

Policy Name (Box)
INTE E14-2 2015
Costa Rica
Americas
Mandatory
Comparative Label
Entered into force , Adopted & Revised
The purpose of this standard is to establish the requirements that must be met by the energy efficiency label of air conditioners. This Standard covers all air conditioners; window type; split; package with nominal cooling capacities up to 17 589 W
Electricity
Room ACs - Stationary ACs
ISO 5151

INTE E14-1 2015

Policy Name (Box)
INTE E14-1 2015
Costa Rica
Americas
Mandatory
Minimum Performance Standard
Entered into force , Adopted & Revised
This standard aims to establish the energy efficiency ranges of air conditioners. This Standard covers all split-window air conditioners with rated cooling capacities up to 17 589 W.
Electricity
Room ACs - Stationary ACs
ISO 5151

INTE E13-2 2018

Policy Name (Box)
INTE E13-2 2018
Costa Rica
Americas
Mandatory
Comparative Label
Entered into force , Adopted & Revised
This standard establishes the labeling requirements for the associated nominal and minimum efficiency values ??of the efficiency of alternating current; three-phase induction motors. This standard applies to electric motors of alternating current; three-phase; induction; squirrel cage; in nominal power of 0.746 kW up to 373 kW; with nominal voltage of up to 600 V; 60 Hz open and closed; horizontal mounting position or vertical.
Electricity
3-Phase Motors

INTE E13-1 2017

Policy Name (Box)
INTE E13-1 2017
Costa Rica
Americas
Mandatory
Minimum Performance Standard
Entered into force , Adopted & Revised
This standard establishes the associated nominal and minimum efficiency values; the test method for its evaluation; and the labeling specification of the nominal efficiency; on the motor data plate. This standard applies to electric motors of alternating current; three-phase; induction; squirrel cage; in nominal power of 0.746 kW up to 373 kW; with nominal voltage of up to 600 V; 60 Hz open and closed; horizontal mounting position or vertical.
Electricity
3-Phase Motors

INTE E12-2 2015

Policy Name (Box)
INTE E12-2 2015

Nominal power up to 110 W inclusive; rated network voltage for compact and circular fluorescent lamps with 120 V or 240 V ballast; at a frequency of 60 Hz; edison; bayonet; G; and any other type.

Costa Rica
Americas
Mandatory
Comparative Label
Entered into force , Adopted & Revised
This standard establishes the minimum content of the energy efficiency label, compact and circular fluorescent lamps -CFL. This national standard applies to compact fluorescent lamps without enclosures; with enclosures and with integrated reflectors of T5 diameter or smaller; with integrated electromagnetic or electronic ballast; with the following characteristics: Nominal power up to 110 W inclusive; rated network voltage for compact and circular fluorescent lamps with 120 V or 240 V ballast; at a frequency of 60 Hz; edison; bayonet; G; and any other type.
Electricity
Non-Directional lamps

INTE E12-1 2015

Policy Name (Box)
INTE E12-1 2015

Nominal power up to 110 W inclusive; rated network voltage for compact and circular fluorescent lamps with 120 V or 240 V ballast; at a frequency of 60 Hz; edison; bayonet; G; and any other type.

Costa Rica
Americas
Mandatory
Minimum Performance Standard
Entered into force , Adopted & Revised
This standard establishes the minimum efficiency limits for compact and circular fluorescent lamps -CFL. This national standard applies to compact fluorescent lamps without enclosures; with enclosures and with integrated reflectors of T5 diameter or smaller; with integrated electromagnetic or electronic ballast; with the following characteristics: Nominal power up to 110 W inclusive; rated network voltage for compact and circular fluorescent lamps with 120 V or 240 V ballast; at a frequency of 60 Hz; edison; bayonet; G; and any other type.
Electricity
Non-Directional lamps
ISO 3951-1

INTE E11-2 2015

Policy Name (Box)
INTE E11-2 2015
Costa Rica
Americas
Mandatory
Comparative Label
Entered into force , Adopted & Revised
This standard specifies the label of energy consumption and its contents of household refrigerators and freezers operated by hermetic motor compressor. This standard applies to refrigerators up to 1104 liters and freezers up to 850 liters operated by hermetic motor compressors.
Electricity
Refrigerators-Freezers
Freezers-only

INTE E11-1 2015

Policy Name (Box)
INTE E11-1 2015
Costa Rica
Americas
Mandatory
Minimum Performance Standard
Entered into force , Adopted & Revised
This standard establishes the maximum limits of energy consumption of residential refrigerators and freezers operated by hermetic motor compressors. This standard applies to refrigerators up to 1104 L and freezers up to 850 L operated by hermetic motor compressors. This standard does not apply to refrigerator-freezers with partially automatic defrosting.
Electricity
Refrigerators-Freezers
Freezers-only

INTE E10-2 2015

Policy Name (Box)
INTE E10-2 2015

This modification includes imported used and reconstructed equipment. This standard does not include used or reconstructed national equipment. This standard also applies to vertical refrigerators that are used with loads at temperatures down to -5C.

Costa Rica
Americas
Mandatory
Comparative Label
Entered into force , Adopted & Revised
This standard applies to the following self-contained commercial refrigeration equipment powered by electricity; new -imported and domestic; used and rebuilt -only imported. All with capacities of 10 liters of refrigerated volume useful -in function of the energetic limits- or more. The types of equipment are: Vertical coolers with one or more front doors; Horizontal coolers; Horizontal freezers; Vertical freezers; Closed showcases; Ice bag preservers. This modification includes imported used and reconstructed equipment. This standard does not include used or reconstructed national equipment. This standard also applies to vertical refrigerators that are used with loads at temperatures down to -5C.
Electricity
Refrigerators-Freezers

INTE E10-1 2015

Policy Name (Box)
INTE E10-1 2015
Costa Rica
Americas
Mandatory
Minimum Performance Standard
Entered into force , Adopted & Revised
This standard establishes the specifications to determine the values of energy consumption per liter for self-contained commercial refrigeration equipment.
Electricity
Refrigerators-Freezers