Policy Details

MEPS for General Lighting
Source
This policy sets minimum energy performance requirements for the following products: incandescent lamps (25-200W), Compact fluorescent lamps with integrated ballast (CFLi) (up to 60W), LED lamps with an Edison screw or a bayonet lamp cap (up to 60W), Compact fluorescent lamps without integrated ballast (CFLni), T8 Linear, double-capped, fluorescent lamps (LFL)[0.5 - 1.5]m, and LED lamps designed as a direct replacement for CFLni and T8 LFL without requiring any internal modification of the luminaires.
  • Incandescent lamp  (25-200W):  0.24 √ɸ + 0.0103ɸ
  • Compact fluorescent lamp with integrated ballast (CFLi)  (up to 60W): 
    • 0.24 √ɸ + 0.0103ɸ
    • CFLi
      • The ratio of luminous flux emitted by the lamps at 2,000 hours to its initial luminous flux is ≥ 0.85; and
      • The fraction of the total number of lamps that continue to operate (light output must be at least 50% of its initial luminous flux) at 6,000 hours is  ≥ 0.5.
      • Covered CFLI
        • The ratio of luminous flux emitted by the lamps at 2,000 hours to its initial luminous flux is ≥ 0.8; and
        • The fraction of the total number of lamps that continue to operate (light output must be at least 50% of its initial luminous flux) at 6,000 hours is   ≥ 0.5.

LED lamp with an Edison screw or a bayonet lamp cap (up to 60W):

  • 0.24 √ɸ + 0.0103ɸ
  • The ratio of luminous flux emitted by the lamp at 6,000 hours2 to its initial luminous flux is ≥ 0.8; and
  • The fraction of the total number of lamps that continue to operate (light output must be at least 70% of its initial luminous flux) at 6,000 hours is ≥ 0.9.

Compact fluorescent lamp without integrated ballast (CFLni)

  • The ratio of luminous flux emitted by the lamp at 2,000 hours to its initial luminous flux is ≥ 0.8; and
  • The fraction of the total number of lamps that continue to operate (light output must be at least 50% of its initial luminous flux) at 2,000 hours is ≥ 0.9.

T8 Linear, double-capped, fluorescent lamp (LFL) [0.5 - 1.5]m

  • The ratio of luminous flux emitted by the lamp at 2,000 hours to its initial luminous flux is ≥ 0.8; and
  • The fraction of the total number of lamps that continue to operate (light output must be at least 50% of its initial luminous flux) at 2,000 hours is ≥ 0.9.

LED lamp designed as a direct replacement for CFLni and T8 LFL without requiring any internal modification of the luminaires

  • The ratio of luminous flux emitted by the lamp at 6,000 hours2 to its initial luminous flux is ≥ 0.8; and
  • The fraction of the total number of lamps that continue to operate (light output must be at least 70% of its initial luminous flux) at 6,000 hours is ≥ 0.9.

 

Δɸ is the rated luminous flux in lumen.

For covered CFLi, Plamp = Pcovered CFLi x 0.95

2Registered suppliers must declare compliance at 6,000 hours if samples are tested to 1,000 hours only.

A minimum sample size of 20 is required.

If you are selling or supplying the following lamps, please ensure that they meet the applicable safety standards

See more
Asia and Pacific
Singapore*
Mandatory
Minimum Performance Standard
Adopted & Revised
Adopted
Revised
Updated by CLASP
National Environment Agency
CIE3 84:1989 and IEC 60064, Measurement of luminous flux
CIE 84:1989 and IEC 60064 or IEC 60357, Measurement of luminous flux
IEC 60969:2001, Performance tests
IEC 60901:2001, Performance tests
IEC 60081:2002, Performance tests
IEC 62612:2013, Performance tests
IEC 62612:2013, Performance tests

Fuel Types

Electricity