Greenhouse and Energy Minimum Standards (Self-ballasted Compact Fluorescent Lamps for General Lighting Services) Determination 2017
Greenhouse and Energy Minimum Standards (Gas Water Heaters) Determination 2017
external storage heaters with a nominal gas consumption of less than 50 MJ/h and storage capacity of over 30 litres internal and external instant gas water heaters with a nominal gas consumption of less than 250 MJ/h and a heat output of less than 13.1 kW (equivalent to a delivery rate of 7.5 L/min raised through 25C)
Greenhouse and Energy Minimum Standards (Electric Water Heaters) Determination 2012
The following products are exempt from MEPS: Water heaters that use electric resistive heating to provide less than 50% of the energy supplied in a typical year (eg heat pump and solar water heaters) when simulated to AS 4234 under Climate Zone 3 with an energy delivery of 22.5 MJ/day for an electric boosting element and energisation profile specified by the manufacturer. Water heaters that are not intended for electric power grid connection (eg for use in vehicles and marine applications).
Greenhouse and Energy Minimum Standards (Gas Water Heaters) Determination 2017
Greenhouse and Energy Minimum Standards (Computer Monitors) Determination 2014
Class 1 Computer monitors with a diagonal screen size less than 76 cm (30 inches) and a screen resolution less than or equal to 1.1 MegaPixels. Class 2 Computer monitors with a diagonal screen size less than 76 cm (30 inches) and a screen resolution greater than 1.1 MegaPixels. Class 3 Computer monitors with a diagonal screen size equal to or greater than 76 cm (30 inches) and equal to or less than 152 cm (60 inches)." "
Greenhouse and Energy Minimum Standards (Liquid-chilling Packages Using the Vapour Compression Cycle) Determination 2012
Greenhouse and Energy Minimum Standards (Refrigerated Cabinets) Determination 2024
The energy efficiency index, or EEI, of a refrigerated cabinet that is covered by this instrument is calculated in accordance with the following formula:
where:
AEC is the refrigerated cabinet’s annual energy consumption, in kWh per year, and is calculated in accordance with section 26.
RAEC is the refrigerated cabinet’s reference annual energy consumption, in kWh per year, and is calculated in accordance with section 26.
Note: For refrigerated cabinets that are covered by this instrument, other than low sales volume and/or oversize RDCs and low sales volume RSCs, the reference annual energy consumption is equal to the standard annual energy consumption, which represents the energy consumption of a standard cabinet of the relevant type.
For low sales volume and/or oversize RDCs and low sales volume RSCs, the reference annual energy consumption is equal to the base annual energy consumption, which reflects the energy consumption of a reference low‑efficiency version of a cabinet of the relevant type.
GEMS level requirements:
Star Ratings:
RDCs (short for refrigerated display cabinets);
refrigerated drinks cabinets;
ice cream freezer cabinets;
scooping cabinets;
RSCs (short for refrigerated storage cabinets).
The policy replaces the following determination: Greenhouse and Energy Minimum Standards (Refrigerated Cabinets) Determination 2020
Greenhouse and Energy Minimum Standards (Transformers and Electronic Step-down Converters for ELV Lamps) Determination 2012
(g) welding transformers; (h) three phase transformers with three or more windings per phase; (i) arc-furnace transformers; (j) earthing transformers; (k) rectifier or converter transformers; (l) uninterruptible power supply (ups) transformers; (m) transformers with an impedance less than 3% or more than 8%; (n) voltage regulating transformers; (o) transformers designed for frequencies other than 50 hertz; (p) gas-filled dry-type transformers; or (q) flameproof transformers.