Resolution No.117: central, packaged and split air conditioners

Policy Name (Box)
Resolution No.117: central, packaged and split air conditioners
Panama
Americas
Mandatory
Comparative Label
Minimum Performance Standard
Entered into force & Adopted
This regulation applies to central, packaged and split air conditioners.
Electricity
Room ACs - Stationary ACs
/sites/default/files/styles/widescreen_1920_x_1920/public/policies/label-images/Panama%20Comparative%20Label_2.PNG?itok=SGPFxPuR
DGNTI-COPANIT 101:2017

Resolution No.116: room-type air conditioners

Policy Name (Box)
Resolution No.116: room-type air conditioners
Panama
Americas
Mandatory
Comparative Label
Minimum Performance Standard
Entered into force & Adopted
This regulation applies to room-type air conditioners.
Electricity
Room ACs - Stationary ACs
/sites/default/files/styles/widescreen_1920_x_1920/public/policies/label-images/Panama%20Comparative%20Label_1.PNG?itok=3_sQ2FKo
DGNTI-COPANIT 102:2017

Resolution No.115: ductless split type air conditioners

Policy Name (Box)
Resolution No.115: ductless split type air conditioners
Panama
Americas
Mandatory
Comparative Label
Minimum Performance Standard
Entered into force & Adopted
This regulation applies to ductless split type air conditioners.
Electricity
Room ACs - Stationary ACs
/sites/default/files/styles/widescreen_1920_x_1920/public/policies/label-images/Panama%20Comparative%20Label_0.PNG?itok=TKAYYrkL
DGNTI-COPANIT 103:2017

Resolution No.114: ductless, split type air conditioners with variable refrigerant flow

Policy Name (Box)
Resolution No.114: ductless, split type air conditioners with variable refrigerant flow
Panama
Americas
Mandatory
Comparative Label
Minimum Performance Standard
Entered into force & Adopted
This regulation applies to ductless, split type air conditioners with variable refrigerant flow.
Electricity
Room ACs - Stationary ACs
/sites/default/files/styles/widescreen_1920_x_1920/public/policies/label-images/Panama%20Comparative%20Label.PNG?itok=NAAvFrg9
DGNTI-COPANIT 104:2017

MEPS and labeling schemes for CFL

Policy Name (Box)
MEPS and labeling schemes for CFL
Panama
Americas
Mandatory
Minimum Performance Standard
Comparative Label
Under development
Information not available
Electricity
Non-Directional lamps

NTON 10 017-08 Energy efficiency. Window, split, packaged air conditioners. Energy efficiency ratings

Policy Name (Box)
NTON 10 017-08 Energy efficiency. Window, split, packaged air conditioners. Energy efficiency ratings
Nicaragua
Americas
Mandatory
Minimum Performance Standard
Entered into force & Adopted
This standard specifies the MEPS for window air conditioners, split air conditioners, packaged air conditioners with nominal cooling capacities of up to 17,589 W (60,000 Btu/h).
Electricity
Room ACs - Stationary ACs

NTON 10 013-08 Energy efficiency. Household refrigerators and freezers. Limits

Policy Name (Box)
NTON 10 013-08 Energy efficiency. Household refrigerators and freezers. Limits
Nicaragua
Americas
Mandatory
Minimum Performance Standard
Entered into force & Adopted
This standard specifies the MEPS for household refrigerators up to 1104 L (39 feet) and household freezers up to 850 L (30 feet) operated by hermetic motor compressor.
Electricity
Refrigerators-Freezers
Freezers-only
NTON 10-015-08

NTON 10 010-08 Self-contained commercial refrigeration equipment

Policy Name (Box)
NTON 10 010-08 Self-contained commercial refrigeration equipment
Nicaragua
Americas
Mandatory
Minimum Performance Standard
Entered into force & Adopted
This standard specifies the MEPS for self-contained commercial refrigeration equipment powered by electricity, used, rebuilt (imported only) and new. All with capacities from 10 liters (0.01 m3 ) of useful refrigerated volume (depending on energy limits) or more. The types of equipment are:
Electricity
Refrigerated Cabinets
Refrigerators-Freezers
Freezers-only
NTON 10-12-08, ISO 23953-1, ISO 3951

NTON 10 008-08 Energy efficiency. Self-ballasted compact fluorescent lamps. Requirements

Policy Name (Box)
NTON 10 008-08 Energy efficiency. Self-ballasted compact fluorescent lamps. Requirements
Nicaragua
Americas
Mandatory
Minimum Performance Standard
Entered into force & Adopted
This standard specifies the MEPS for compact fluorescent lamps of hot cathode and integrated ballast, with socket that allows them to be placed in conventional incandescent lampholders (E-26 and E-27), at a nominal voltage between 110 V - 240 V, of alternating current and at a frequency of 60 Hz, with nominal power between 5W and 110 W. This standard does not apply to colored, anti-insect and special ultraviolet radiation lamps.
Electricity
Non-Directional lamps
IEC 60061, IEC 60969, ANSI C78.5-2003, ANSI C78.375-199

NTON 10 007-08 Energy efficiency. Three-phase squirrel-cage AC induction motors with a rated output of 0.746 to 373 kW. Limits, test methods and labeling requirements

Policy Name (Box)
NTON 10 007-08 Energy efficiency. Three-phase squirrel-cage AC induction motors with a rated output of 0.746 to 373 kW. Limits, test methods and labeling requirements
Nicaragua
Americas
Mandatory
Minimum Performance Standard
Entered into force & Adopted
This standard specifies the MEPS and labeling requirements for open- and closed-loop three-phase squirrel-cage electric AC induction motors with a rated output of 0.746 kW to 373 kW, nominal electric voltage up to 600 V, 60 Hz, horizontal mounting position or vertical.
Electricity
3-Phase Motors