NOM-017-ENER/SCFI-2012

Policy Name (Box)
NOM-017-ENER/SCFI-2012
Mexico
Americas
Mandatory
Minimum Performance Standard
Entered into force , Adopted & Revised
This Official Mexican Standard applies to all self-ballasted compact fluorescent lamps without enclosure, with enclosure and reflector integrated with any type of base, in voltages from 100 V to 277 V c.a. and 50 Hz or 60 Hz, which are manufactured, imported or traded on the national territory.
Electricity
Non-Directional lamps
NOM-017-ENER/SCFI-2012

Standard NOM-016-ENER-2016 - Three Phase Motors

Policy Name (Box)
NOM-016-ENER-2016, Energy efficiency of alternating current motors , three-phase,induction, squirrel cage type, in nominal power from 0.746 kW to 373 kW. Limits, test method and marking.
Mexico
Americas
Mandatory
Minimum Performance Standard
Entered into force , Adopted & Revised
Standard NOM-016-ENER-2016 applies to alternating current, three-phase, induction, squirrel cage type electric motors, with a rated output of 0.746 kW to 373 kW, with nominal electrical voltage up to 600 V, open or closed, single frequency (speed of rotation on the motor shaft or shaft) of rotation, horizontal mounting position or vertical, air-cooled and continuous regime, marketed in national territory.
Electricity
3-Phase Motors
NOM-008-SCFI / NOM-106-SCFI-2000

NOM-015-ENER-2018

Policy Name (Box)
NOM-015-ENER-2018
Mexico
Americas
Mandatory
Minimum Performance Standard
Entered into force & Adopted
The Standard establishes the maximum energy consumption limits, labeling requirements, and test methods for household refrigerators, freezers, refrigerator-freezers operated by hermetic motor compressors sold in Mexico.
Electricity
Refrigerators-Freezers
Freezers-only
NOM-015-ENER-2018

Standard NOM-015-ENER-2012 - Domestic Refrigerators and Freezers

Policy Name (Box)
NORMA OFICIAL MEXICANA NOM-015-ENER-2012, EFICIENCIA ENERGETICA DE REFRIGERADORES Y CONGELADORES ELECTRODOMESTICOS. LIMITES, METODOS DE PRUEBA Y ETIQUETADO
Mexico
Americas
Mandatory
Comparative Label
Minimum Performance Standard
Entered into force & Adopted
This policy covers labeling and minimum efficiency requirements for electric household refrigerators and freezers.
Electricity
Refrigerators-Freezers
Freezers-only
/sites/default/files/styles/widescreen_1920_x_1920/public/policies/label-images/Mexico%20Comparative%20Label_3.PNG?itok=CFIxf1cW
NOM-15-ENER-2012

NOM-014-ENER-2004

Policy Name (Box)
NOM-014-ENER-2004
Mexico
Americas
Mandatory
Minimum Performance Standard
Entered into force , Adopted & Revised
Standards NOM-014-ENER-2004 applies to single-phase squirrel cage air-cooled induction AC motors with a rated output of 0.180 kW to 1.500 kW, with single rotation frequency, 2, 4 or 6 poles, split phase or capacitor start, open or closed.
Electricity
1-Phase Motors

Standard NOM-011-ENER-2006 - Air Conditioners

Policy Name (Box)
NORMA OFICIAL MEXICANA NOM-011-ENER-2006, EFICIENCIA ENERGETICA EN ACONDICIONADORES DE AIRE TIPO CENTRAL, PAQUETE O DIVIDIDO. LIMITES, METODOS DE PRUEBA Y ETIQUETADO
Mexico
Americas
Mandatory
Comparative Label
Minimum Performance Standard
Entered into force , Adopted & Revised
This policy covers labeling and minimum efficiency requirements for central, package and split type air conditioners, powered by electricity, with nominal cooling capacities of 8,800W to 19,050W, which operate by mechanical compression and which include an air-cooling evaporator coil, a compressor and either an air- or water-cooled condensing coil. Standard NOM-011-ENER-2006 applies to central, package and split type air conditioners, powered by electricity, with nominal cooling capacities of 8,800W to 19,050W, which operate by mechanical compression and which include an air-cooling evaporator coil, a compressor and either an air- or water-cooled condensing coil.
Electricity
Packaged Terminals
Central ACs
/sites/default/files/styles/widescreen_1920_x_1920/public/policies/label-images/Mexico%20Comparative%20Label_2.PNG?itok=TX4aVAXT
NOM-008-SCFI-2002 / NOM-050-SCFI-2004

NOM-010-ENER-2004

Policy Name (Box)
NOM-010-ENER-2004
Mexico
Americas
Mandatory
Minimum Performance Standard
Entered into force , Adopted & Revised
Standard NOM-010-ENER-2004 applies to submersible deep well type clean water motor pumps operated by a submersible three-phase electric motor. The standard does not apply to sewage and mud pumps.
Electricity
Pumps Other
NOM-010-ENER-2004

NOM-005-ENER-2016

Policy Name (Box)
NOM-005-ENER-2016, Energy efficiency of household appliance washing machines. Limits, test methods and labeling.
Mexico
Americas
Mandatory
Comparative Label
Minimum Performance Standard
Entered into force , Adopted & Revised
This policy covers labeling and minimum efficiency requirements for household electric clothes washers.
Electricity
Washing Machines
/sites/default/files/styles/widescreen_1920_x_1920/public/policies/label-images/Mexico%20Comparative%20Label_1.PNG?itok=7uqhkl1w
NMX-J-585-ANCE-2014

Standard NOM-004-ENER-2014 - Domestic Water Pumps

Policy Name (Box)
NORMA OFICIAL MEXICANA NOM-004-ENER-2014, EFICIENCIA ENERGÉTICA PARA EL CONJUNTO MOTOR-BOMBA, PARA BOMBEO DE AGUA LIMPIA DE USO DOMÉSTICO, EN POTENCIAS DE 0,180 kW (¼ HP) HASTA 0,750 kW (1 HP) - LÍMITES, MÉTODOS DE PRUEBA Y ETIQUETADO
Mexico
Americas
Mandatory
Comparative Label
Minimum Performance Standard
Entered into force , Adopted & Revised
This policy covers labeling and minimum efficiency requirements for residential water pumps and residential water motor pumps (using single-phase squirrel-cage induction motors), respectively, and the test methods for verifying compliance therewith. Standard NOM-004-ENER-2014 applies to clean-water pumps and motor pumps with a power rating of 0.187 kW to 0.746 kW.
Electricity
Pumps Other
/sites/default/files/styles/widescreen_1920_x_1920/public/policies/label-images/Mexico%20Comparative%20Label_0.PNG?itok=qjCVFplA
NOM-004-ENER-2008

Standard NOM-003-ENER-2011 - Domestic and Commercial Water Heaters

Policy Name (Box)
NORMA OFICIAL MEXICANA NOM-003-ENER-2011, EFICIENCIA TERMICA DE CALENTADORES DE AGUA PARA USO DOMESTICO Y COMERCIAL. LIMITES, METODO DE PRUEBA Y ETIQUETADO
Mexico
Americas
Mandatory
Comparative Label
Minimum Performance Standard
Entered into force & Adopted
This policy covers labeling and minimum efficiency requirements for domestic and commercial water heaters which use LPG or natural gas with a heat load <= 108kW. It includes the product classes: storage, quick recovery and instantaneous water heaters. Standards NOM-003-ENER-2011 applies to water heaters for domestic and commercial use which use LPG or natural gas with a heat load <= 108 kW. It includes the product classes: storage, quick recovery and instantaneous water heaters.
Gas
Instantaneous Water Heaters
Storage Water Heaters
/sites/default/files/styles/widescreen_1920_x_1920/public/policies/label-images/Mexico%20Comparative%20Label.PNG?itok=Wn-hnmJC
NOM-003-ENER-2011