Energy Efficiency Policy for Ceiling Fans

Policy Name (Box)
Energy Efficiency Policy for Ceiling Fans

Star labeling requirements for ceiling fans

India
Asia and Pacific
Mandatory
Comparative Label
Minimum Performance Standard
Entered into force , Adopted & Revised
This policy defines star labeling requirements and minimum energy perfomance requirements for electric ceiling type fans operated by induction motors and Brushless Electric Motors of all the standard sweep sizes covered under the scope of IS 374: 2019 ( 900 mm, 1050 mm, 1200 mm, 1400 mm, 1500 mm) as amended from time to time that work on single phase alternating current supply up to and including 250V, 50Hz, being manufactured, commercially purchased, imported or sold in India.
Electricity
Space Heating and Space Cooling
Ventilation
Ceiling Fans
/sites/default/files/styles/widescreen_1920_x_1920/public/policies/label-images/India%20Comparative%20Label%20for%20Ceiling%20Fans.png?itok=_VoyW2u6
IS 374:2019

Schedule 7 - Agricultural Pump Sets

Policy Name (Box)
Schedule 7 - Agricultural Pump Sets
India
Asia and Pacific
Voluntary
Comparative Label
Minimum Performance Standard
Entered into force , Adopted & Revised
This schedule specifies the MEPS and labeling instructions for single phase of rating up to 2.2 kW and three phase pump sets of ratings 1. kW to 75 kW covering Electric mono set pumps, submersible pump sets and open well submersible pump sets
Electricity
Agricultural Pumps
/sites/default/files/styles/widescreen_1920_x_1920/public/policies/label-images/India%20Comparative%20Label%20Agricultural%20Pump%20Set.png?itok=5y-MHNAy
IS 9079:2002, IS 8034:2002, IS 14220:1994, IS 11346:2002

Schedule 6 - Induction Motors

Policy Name (Box)
Schedule 6 - Induction Motors
India
Asia and Pacific
Voluntary
Comparative Label
Minimum Performance Standard
Entered into force & Adopted
This schedule specifies the MEPS and labeling instructions for 3 phase squirrel cage induction motor in 2 Pole, 4 Pole and 6 Pole of ratings up to 375 kW for continuous duty (S1) operation, suitable for voltage and frequency variation as per IS 12615:2011
Electricity
3-Phase Motors
/sites/default/files/styles/widescreen_1920_x_1920/public/policies/label-images/India%20Comparative%20Label%20for%20Induction%20Motors.png?itok=T0TikkOL
IS 12615:2011, IS IEC 60034-2-1, IS 15999:2011

Schedule 22 - Microwave Ovens

Policy Name (Box)
Schedule 22 - Microwave Ovens
India
Asia and Pacific
Voluntary
Comparative Label
Minimum Performance Standard
Entered into force & Adopted
This schedule specifies the MEPS and labeling instructions for microwave ovens (including combination microwave ovens) meant for household or similar use, with or without grill or convection functions, being manufactured, imported or sold in India. This schedule applies to all types of counter-top microwave oven (covered under the scope of IS 302-2-25, and IEC 60705). The label is expected to be voluntary until the end of 2020, and become mandatory in 2021.
Electricity
Microwaves
/sites/default/files/styles/widescreen_1920_x_1920/public/policies/label-images/India%20Comparative%20Label%20for%20Microwave%20Ovens.png?itok=ugtW23Sp
IEC 60705: Amendment 1, 2010 and Amendment 2, 2018, IEC 62301, IS 302-2-25

Schedule 21 - Chillers

Policy Name (Box)
Schedule 21 - Chillers

This schedule specifies the MEPS and labeling instructions for chillers working on vapour compression cycle, manufactured in India or imported for sale in India for central cooling and similar use. The schedule covers all types and sizes/capacity for rated voltage up to and including 250 V, 50 Hz AC, for single phase and up to and including 415V, 50Hz AC for three phase power supply covered under the scope of IS 16590. For this schedule, the star rating shall be based on Indian Seasonal Energy Efficiency Ratio (ISEER) and full load COP as the prequalification criteria.

India
Asia and Pacific
Voluntary
Comparative Label
Minimum Performance Standard
Entered into force & Adopted
This schedule specifies the MEPS and labeling instructions for water cooled chillers manufactured in India or imported for sale in India for central cooling and similar use.
Electricity
Chillers - Cooler Towers
/sites/default/files/styles/widescreen_1920_x_1920/public/policies/label-images/India%20Comparative%20Label%20for%20Chillers.png?itok=WFYZFGT2
IS 16590:2017

Schedule 18 - Diesel Generator Sets

Policy Name (Box)
Schedule 18 - Diesel Generator Sets

It excludes generating sets used on aircraft or to propel land vehicles and Locomotives. Diesel Generating (DG) Sets up to 19 kW ratings are covered under pilot energy labeling scheme for single/three phase DG Sets.

India
Asia and Pacific
Voluntary
Comparative Label
Minimum Performance Standard
Entered into force , Adopted & Revised
This schedule specifies the star labeling requirements for various classifications for the application, rating and performance of single/three phase Diesel Generating sets consisting of a Reciprocating Internal Combustion (RIC) engine driven by diesel as fuel, Alternating Current (a.c.) generator, any associated control gear, switchgear and auxiliary equipment. It applies to A. C. generating sets driven by RIC engines for land and marine use being manufactured, imported or sold in India. It excludes generating sets used on aircraft or to propel land vehicles and Locomotives. Diesel Generating (DG) Sets up to 19 kW ratings are covered under pilot energy labeling scheme for single/three phase DG Sets.
Oil
External Power Supply
/sites/default/files/styles/widescreen_1920_x_1920/public/policies/label-images/India%20Comparative%20Label%20for%20Diesel%20Generators.png?itok=lXnLzpUV
IS 10000, IS 10001, IS 13364, IS 4889:1968

Schedule 17 - Solid state inverters

Policy Name (Box)
Schedule 17 - Solid state inverters

Note: Inclusion of Solid State Inverters run from Storage Batteries of 24 Volts Direct Current source is under consideration.

India
Asia and Pacific
Voluntary
Comparative Label
Minimum Performance Standard
Entered into force & Adopted
This schedule specifies the minimum DC to AC efficiency and labeling instructions for Solid State Inverters run from Storage Batteries of 12 Volts Direct Current source being manufactured, imported or sold in India. The output rating of the Solid State Inverters run from Storage Batteries, covered under this schedule shall be between 250 VA to 2000 VA for continuous output. Note: Inclusion of Solid State Inverters run from Storage Batteries of 24 Volts Direct Current source is under consideration.
Electricity
Solar Inverters
/sites/default/files/styles/widescreen_1920_x_1920/public/policies/label-images/India%20Comparative%20Label%20for%20Inverters.png?itok=lolM2_pw
IS 13314:1992

Schedule 16 - Office Equipments (printers, scanners, copiers, fax machines and multi function devices)

Policy Name (Box)
Schedule 16 - Office Equipments (printers, scanners, copiers, fax machines and multi function devices)
India
Asia and Pacific
Voluntary
Endorsement Label
Entered into force & Adopted
The schedule specifies the MEPS and labeling instructions for office equipment copiers, printers, fax machines, scanners and multi-function devices for office automation and similar use. This schedule is for only single phase office equipment (printers, scanners, copiers, fax machines and multi-function devices) which operate at the standard voltage and frequency range specified by the relevant Indian Standards and the Indian Electricity Rules 1956.
Electricity
Imaging Equipment
/sites/default/files/styles/widescreen_1920_x_1920/public/policies/label-images/India%20Endorsement%20Label_0.png?itok=JEtpqn5O
IEC 62301:2011

Schedule 15 - Ballasts

Policy Name (Box)
Schedule 15 - Ballasts

This schedule also include built in ballasts where the ballast is inbuilt in the luminaire. The ballasts which are integral to the lamps are excluded from the scope of this schedule.

India
Asia and Pacific
Voluntary
Comparative Label
Minimum Performance Standard
Entered into force , Adopted & Revised
This schedule specifies the MEPS and labeling instructions for ballasts covering electromagnetic ballasts and electronic ballasts for single and double capped tubular fluorescent lamps (TFL).
Electricity
Fluorescent and HID Lighting
/sites/default/files/styles/widescreen_1920_x_1920/public/policies/label-images/India%20Comparative%20Label%20for%20Ballasts.png?itok=siNhKr73
IS 1534 (Part 1):1977, IS 13021 (Part 1 & 2):1991

Schedule 14 - Laptop/Notebook Computers

Policy Name (Box)
Schedule 14 - Laptop/Notebook Computers

In the absence of BIS standard for laptops and notebooks this standard follows the version 6.11 - Energy Star program requirements Product specification for computers.

India
Asia and Pacific
Voluntary
Endorsement Label
Entered into force & Adopted
This schedule specifies the MEPS and energy labeling instructions for desktops, integrated desktops and notebook/ laptop computers, manufactured, imported, or sold in India for household/office and similar use. This Standard has been prepared on the basis of Energy Star specification for computers developed by US Environment Protection Agency. In the absence of BIS standard for laptops and notebooks this standard follows the version 6.11 - Energy Star program requirements Product specification for computers.
Electricity
Computers
/sites/default/files/styles/widescreen_1920_x_1920/public/policies/label-images/India%20Endorsement%20Label.png?itok=pBaOM7vM
version 6.1 - Energy Star program requirements Product specification for computers